Delivering excellent uncorrected visual acuity (VA) at all distances,1 the TECNIS Symfony® IOL allows your patients to see clearly across a full range of vision.

Defocus Curve1

6-Month Data, Bilaterally Implanted Subjects

 

  • Sustained 20/25 or better mean VA through 1.5 D
  • Sustained 20/40 or better mean VA through 2.5 D
  • Increase of 1.0 D range of vision throughout the defocus curve

Rather than splitting light into distinct focal points, the TECNIS Symfony® IOL elongates focus, resulting in an increased depth of field. This empowers you to deliver a full range of continuous vision while maintaining high image contrast.

Monocular Contrast Sensitivity at 6 Months1

Mesopic without Glare

Enhanced Functionality

Deliver the visual quality that allows your patients with and without astigmatism to see clearly in any lighting condition.

  • High-quality distance vision in the presence of astigmatism2
  • Pupil-independent performance enables optimal performance in any lighting condition1
  • Low overall spectacle wear1

The TECNIS Symfony® IOL delivers 20/20 or better vision through 1.5 D of astigmatism.1

85% of patients wear glasses none or a little bit of the time.1

By combining a unique diffractive pattern with achromatic technology, the TECNIS Symfony® IOL delivers outstanding visual acuity over a continuous range of distances while maintaining high contrast performance.

  • Proprietary relief profile elongates focus1
  • Proprietary achromatic technology corrects chromatic aberration and enhances image contrast1

Degree of Difficulty with Visual Symptoms1

Percentage of Eyes, Non-Directed Reports, 6 Months Postoperative

 

Low incidence of visual symptoms, including halos, glare and starbursts1

Long-Term Sustainability

Unlike another leading IOL, TECNIS® IOL material is not associated with glistenings,3-7 which can inhibit your patients’ vision. Glistenings cause light scatter, which can result in a reduction in image contrast.4-8

Specifications

TECNIS Symfony® IOL (ZXR00)

OPTIC CHARACTERISTICS

Powers:

+5.0 D to 34.0 D in 0.5 diopter increments

Diameter:

6.0 mm

Center Thickness:

0.7 mm (20.0 D)

Shape:

Biconvex, wavefront-designed anterior aspheric surface, posterior achromatic diffractive surface designed to reduce chromatic aberration for enhanced image contrast and echelette feature to extend the range of vision.

Material:

UV-blocking hydrophobic acrylic

Refractive Index:

1.47 at 35° C

Edge Design:

ProTEC frosted, continuous 360° posterior square edge

BIOMETRY*

CONTACT ULTRASOUND

OPTICAL

A-Constant:

118.8

119.3 

Theoretical AC Depth:

5.40 mm

5.7 mm

Surgeon Factor:9

1.68 mm

1.96 mm

HAPTIC CHARACTERISTICS

Overall Length:

13.0 mm

Thickness:

0.46 mm

Style:

C

Material:

Soft, foldable, UV-blocking hydrophobic acrylic

Design:

TRI-FIX, haptics offset from optic, one-piece lens

IOL INSERTION

Recommended insertion instruments:

  • UNFOLDER® Platinum 1 Series Delivery System: Intuitive push-and-twist, screw-style insertion designed to simplify lens implantation.
  • UNFOLDER® Emerald Delivery System: Simplified, controlled delivery with large hand wheel, screw-style implantation technique and small threads.
  • One Series Ultra Delivery System: Reliable control with syringe-style insertion designed for optimal stability in implantation.

 