Excellent Outcomes for Patients with Astigmatism
Empower your patients’ vision with proven optical quality. The TECNIS® Monofocal Toric IOL delivers the sharpest vision, best low-light performance and long-term sustainability for patients with astigmatism.
Optimize your outcomes with the TECNIS® Toric Calculator.
Get a grip on visual performance
High-quality performance is just as critical for patients with astigmatism. The TECNIS® Toric IOL not only delivers excellent spherical correction but beautifully sharp vision as well.
Excellent astigmatism correction meets superior image contrast:
MTF at 50 c/mm White, 5 mm Pupil3
Up to 31% improved image contrast.
MTF at 50 c/mm White, 3 mm Pupil3
Up to 16% improved image contrast.
Modular Transfer Function (MTF) is a measure of the amount of contrast transferred by the optics in a visual system. The higher the MTF value, the more contrast transferred to the image, resulting in higher image contrast. AcrySof is a trademark of Novartis AG Corp.
Best Low-Light Performance
TECNIS® Toric IOLs are designed for real-world conditions, empowering you to deliver high-confidence driving at night without distance glasses**2 — as well as the best low-light performance for patients with astigmatism.
Difficulty With Driving at Night Without Glasses at 6 Months†3
91.9% of patients (ZCT150) reported no difficulty with night driving — without glasses.
Long-Term Sustainability
Trust your outcomes to an IOL that delivers exceptional postoperative rotational stability, stunning visual performance and high patient satisfaction.
2.74° mean axis change between baseline and 6 months.2
Unlike another leading IOL, TECNIS® IOL material is not associated with glistenings,4-8 which can inhibit your patients’ vision. Glistenings cause light scatter, which can result in a reduction in image contrast.5-9
97% of patients would elect to have the TECNIS® Toric IOL again.2
Specifications
TECNIS® Toric IOL |
||
Models: |
ZCT150, ZCT225, ZCT300, ZCT400, ZCT450, ZCT525, ZCT600 |
|
OPTIC CHARACTERISTICS |
||
Powers: |
+5.0 D to 34.0 D in 0.5 diopter increments |
|
Diameter: |
6.0 mm |
|
Shape: |
Biconvex, anterior aspheric surface, posterior diffractive surface |
|
Material: |
UV-blocking hydrophobic acrylic |
|
Refractive Index: |
1.47 at 35° C |
|
Chromatic Aberration (Abbe Number): |
55 |
|
Edge Design: |
ProTEC frosted, continuous 360° posterior square edge |
|
BIOMETRY |
CONTACT ULTRASOUND |
OPTICAL |
A-Constant: |
118.8‡ |
119.3§ |
Theoretical AC Depth: |
5.7 mm |
5.72 mm |
Surgeon Factor:10 |
1.68 mm |
1.96 mm |
HAPTIC CHARACTERISTICS |
||
Overall Length: |
13.0 mm |
|
Configuration: |
Tri-Fix design, modified C, integral with optic |
|
Material: |
UV-blocking hydrophobic acrylic |
|
Design: |
Haptics offset from optic |